The Multi-Jet Water Meter features a robust copper-sealed register, providing ultimate protection against fogging and ensuring permanent clear readability in any water quality.
Product Description
Application:
The Multi-Jet Water Meter features a robust copper-sealed register, providing ultimate protection against fogging and ensuring permanent clear readability in any water quality.
Key Features:
• Copper-Sealed Register: Vacuum-sealed to prevent fogging, condensation, and scale.
• Mineral Glass Lens: High-strength glass ensures scratch resistance and permanent clarity.
• Multi-Jet Precision: Ensures long-term measurement precision.
• Corrosion Resistant: Robust brass body resists harsh water quality.
• Magnetic Drive: Reliable transmission ensures smooth operation and anti-tamper security.
• Pressure Resistant: Durable construction suitable for high-pressure domestic applications.
• External Regulation: Allows for precise calibration to maintain metrological performance.
Specifications:
• Body material: Brass
• Accuracy: R80/ R100
• Size: DN15
• Cold water: 0 ℃ - 30℃; 0 ℃ - 50℃
• Hot water: 0 ℃ - 90℃
• Water pressure: 1.0MPa / 1.6MPa
• △P≤63
• Connecting threaded option: G/ BSP/ NPT
• Register: Plastic-sealed/ Copper-sealed
Installation:
• Best installed horizontally with the register facing up for maximum accuracy.
• Ensure the water flow matches the direction of the arrow cast on the body.
• Flush the pipeline thoroughly before installation to remove any debris or stones.
Accuracy:
• From minimum flow rate (Q1) inclusive, to transitional flow rate (Q2) exclusive: ±5%
• From transitional flow rate (Q2) inclusive, to overload flow rate (Q4) exclusive: ±2%
• Hot water meter ±3%
Technical Data:
|
Model |
Unit |
AMT MJB-CS |
|
|
Nominal Size |
mm (inch) |
15 (1/2'') |
|
|
Overload Flow Rate (Q4) |
m3/h |
3.125 |
|
|
Permanent Flow Rate (Q3) |
m3/h |
2.5 |
|
|
R=80 |
Transitional Flow Rate (Q2) |
m3/h |
0.05 |
|
Minimum Flow Rate (Q1) |
m3/h |
0.0312 |
|
|
R=100 |
Transitional Flow Rate (Q2) |
m3/h |
0.04 |
|
Minimum Flow Rate (Q1) |
m3/h |
0.025 |
|
|
Min. Reading |
m3 |
0.0001 |
|
|
Max. Reading |
m3 |
99999 |
|
|
Temperature class |
T °C |
T30/ T50/ T90 |
|
|
Water pressure classes |
MPa |
1.0/1.6 |
|
|
Pressure-loss classes |
|
△P63 |
|
|
Installation positions |
|
HORIZONTAL |
|
Dimension:
|
Model |
Nominal Size (mm) |
Size (inch) |
Length (mm) |
Width (mm) |
Height (mm) |
Connecting Thread D |
Unit weight (Kg) |
PCS/ CTN |
Carton Weight (Kg) |
Carton Dimension (Cm) |
|
AMT MJB-CS |
15 |
1/2″ |
165 |
80.7 |
102 |
G¾B |
0.95 |
10 |
10 |
54x39x14 |