The Volumetric Piston Water Meter achieves high accuracy through direct volume measurement, where a precision piston displaces a known volume per cycle.
The AMT VP Series is MID certified (Measuring Instruments Directive 2014/32/EU) for market-proven, legally compliant accuracy.
Product Description
Application:
The Volumetric Piston Water Meter achieves high accuracy through direct volume measurement, where a precision piston displaces a known volume per cycle.
The AMT VP Series is MID certified (Measuring Instruments Directive 2014/32/EU) for market-proven, legally compliant accuracy.
Key Features:
• Ultra-High Accuracy: Meets high-level metrological classes (e.g., R160/R200/R315).
• Low Starting Flow: Detects minimal water usage with exceptional sensitivity.
• Universal Installation: Maintains precision in horizontal, vertical, or inclined positions.
• Volumetric Principle: Measures the actual volume of water for unmatched reliability.
• Magnetic Drive: Ensures smooth transmission with a vacuum-sealed register.
• Inlet Strainer: Integrated filter protects the precision piston from debris or impurities.
• Non-Return Valve: Prevents backflow and protects against billing tampering.
Specifications:
• Body material: Brass
• Accuracy: R160
• Size: DN15-20
• Cold water: 0 ℃ - 50℃
• Hot water: 0 ℃ - 90℃
• Water pressure: 1.0MPa / 1.6MPa
• △P≤63
• Connecting threaded option: G/ BSP/ NPT
• Pulse output option: 1P=1-10L
Installation:
• Can be installed in any position (horizontal, vertical, or inclined) without affecting accuracy.
• A strainer must be installed to prevent sand or particles from jamming the piston.
• Ensure the pipeline is fully purged of air to avoid measurement errors or rattling.
Accuracy:
• From minimum flow rate (Q1) inclusive, to transitional flow rate (Q2) exclusive: ±5%
• From transitional flow rate (Q2) inclusive, to overload flow rate (Q4) exclusive: ±2%
• Hot water meter ±3%
Technical Data:
|
Model |
Unit |
AMT VP-A |
AMT VP-B |
|
|
Nominal Size |
mm (inch) |
15 (1/2'') |
20 (3/4'') |
|
|
Overload Flow Rate (Q4) |
m3/h |
3.125 |
5 |
|
|
Permanent Flow Rate (Q3) |
m3/h |
2.5 |
4 |
|
|
R=160 |
Transitional Flow Rate (Q2) |
m3/h |
0.025 |
0.04 |
|
Minimum Flow Rate (Q1) |
m3/h |
0.015625 |
0.025 |
|
|
Min. Reading |
m3 |
0.0001 |
0.0001 |
|
|
Max. Reading |
m3 |
99999 |
99999 |
|
|
Temperature class |
T °C |
T50/ T90 |
||
|
Water pressure classes |
MPa |
1.0/1.6 |
||
|
Pressure-loss classes |
|
△P63 |
||
|
Installation Positions |
|
ANY POSITION |
||
|
Flow profile sensitivity classes |
|
U0/D0 |
||
Dimension:
|
Model |
Nominal Size (mm) |
Size (inch) |
Length (mm) |
Width (mm) |
Connecting Thread D |
Unit weight (Kg) |
PCS/ CTN |
Carton Weight (Kg) |
Carton Dimension (Cm) |
|
AMT VP-A |
15 |
1/2″ |
115/165 |
85/87 |
G¾B |
1.0/1.5 |
20 |
20/30 |
46.5x29.5x20 |
|
AMT VP-B |
20 |
3/4″ |
130/165 |
86/90 |
G1 B |
1.3/1.7 |
20 |
26/34 |
46.5x34x20 |